Tuntas Dhanardhono
Unknown Affiliation

Published : 20 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 2 Documents
Search
Journal : Dentino: Jurnal Kedokteran Gigi

THE EFFECT OF HIGH TEMPERATURE HEATING ON WEIGHT AND COLOR CHANGES IN COMPOSITE RESIN AS FORENSIC IDENTIFICATION Farhan Jordan Akbar; Ira Anggar Kusuma; Tuntas Dhanardhono; Yoghi Bagus Prabowo
Dentino : Jurnal Kedokteran Gigi Vol 7, No 2 (2022)
Publisher : FKG Unlam

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20527/dentino.v7i2.14623

Abstract

Background: Fire disaster is a non-natural disaster that often occurs. The impact is that victims are difficult to identify. One of the identification methods that can be used is dental restorative materials with observing changes in color and weight that occur in dental restorative materials due to exposure to high temperatures. Composite resin is a dental restorative material that is often used because it has good aesthetics, physical and mechanical properties. Purpose: This study to determine the effect of high temperature on weight and color changes in nanohybrid and bulkfill composite resin as a reference for forensic identification. Method: This research is an experimental laboratory with a pre and post-test control group design. A total of 30 nanohybrid composite resin samples and 30 bulkfill composite resin samples were divided into 5 groups consisting of 4 treatment groups and 1 control group. The treatment group was heated at four temperature groups, 30°C-200°C, 30°C- 400°C, 30°C-800°C and 30°C-1100°C using a furnace (Thermo Scientific, USA). Weight changes were measured using a digital scale (Ohaus,China) and color changes were observed using the Shade Guide (Vitapan Classical, Germany). Result: A change in color and weight of the nanohybrid composite resin and bulkfill after being heated at high temperatures. Two-Way ANOVA test and Post Hoc LSD test showed that there was a significant difference in weight between nanohybrid composite resin and bulk fill composite resin at each temperature interval (p<0.001). Conclusions: High temperature heating affects the color and weight changes of nanohybrid and bulkfill composite resin. Keywords: Bulkfill composite resin, High temperature heating, Nanohybrid composite resin 
THE EFFECTS OF HIGH TEMPERATURE HEATING ON COLOUR AND WEIGHT CHANGES IN GIC AND RMGIC (A STUDY TO SUPPORT IDENTIFICATION OF FIRE VICTIMS) Nia Damayanti; Ira A. Kusuma; Tuntas Dhanardhono; Brigitta Natania
Dentino : Jurnal Kedokteran Gigi Vol 7, No 2 (2022)
Publisher : FKG Unlam

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20527/dentino.v7i2.14629

Abstract

Background: The temperature reached by fire disaster was varies. The disaster can cause fatalities and thus human identification is required. Dental restorative materials have properties that are resistant to high temperatures and play a role in identification process of fire victims. The identification process can be observed from the change in colour and weight of the restorative material. GIC and RMGIC are some of the most commonly used restorative material because they have good aesthetics properties, biocompatible, economical, and can release fluoride.  Purpose: To determine the effect of high temperature heating on colour and weight changes in GIC and RMGIC as a support for forensic identification. Method: A total of 30 GIC and RMGIC samples used in this study were made in the form of cylinder with a size 3x2 mm. Each material was heated at four temperature groups of 30°C-200°C, 30°C-400°C, 30°C-800°C dan 30°C-1100°C using a furnace. The study was continued with the examination of colour using the Vitapan Classical Shade Guide and weight changes using a digital scale. Results: GIC and RMGIC experienced changes in colour and weight changes due to hight temperatures of 30°C-200°C, 30°C-400°C, 30°C-800°C dan 30°C-1100°C. High temperature heating shows the difference of each material. This is indicated by the p value <0,001 in the Two Way Anova Test and Post Hoc LSD which means that there is a significant difference in weight difference between GIC and RMGIC at each temperature interval. Conclusion: High temperature heating affects the colour and weight changes of GIC and RMGIC.  Keywords: Forensic identification, GIC, High temperature heating, RMGIC